Exception in DbgBreakPoint with TN5250 Service
Symptoms
An application exception (trap) may occur on the SNA Server computer when you use the Rumba 5.2 TN5250 client to connect to the TN5250 Service. If you have Dr. Watson (Drwtsn32.exe) configured as the default debugger, a Drwtsn32.log file is created in the [NTROOT] directory. The following events are created in the Application event log of the Event Viewer:
Event ID: 5
Source : SNA TN5250 ServerDescription:
The SNA TN5250 Service detected an internal error.
File = ..\shared\tn5tnspm.c
Line = 3477
Fail = ((NB_IPS *)dsi5_data)->buf_size >= ((NB_IPS *)dsi5_data)->ips_length
Parm = 0×0
Event ID: 4097
Source: DrWatson
The application, exe\tn5250.dbg, generated an application error The error occurred on1/25/2000 @ 20:58: 3.406.
The exception generated was 80000003 at address 77f76274 (DbgBreakPoint).The following is an example of the exception in DbgBreakPoint:
Application exception occurred:App: exe\tn5250.dbg (pid=326)When: 1/25/2000 @ 20:58:3.406Exception number: 80000003 (hardcoded breakpoint)function: DbgBreakPointFAULT ->77f76274 ccint377f76275 c3ret77f76276 8bc0moveax,eax
Resolution
To resolve this problem, obtain the latest service pack for SNA Server 4.0. For additional information, click the following article number to view the article in theMicrosoft Knowledge Base:
215838?(http://support.microsoft.com/kb/215838/EN-US/) How to Obtain the Latest SNA Server Version 4.0 Service Pack

Leave a Reply